• High efficiency through optimized recuperator shape
• High flame speed
• Designed to facilitate maintenance
• Five sizes with range of performance 51,000 – 850,000 BTU (15 – 250 kW)
• Suitable for all types of gas including natural gas, liquid gas and with a special modification for low calorific gases.
• Direct electrical ignition
• Flame supervision by ionization of UV Cell
• Minimal Nox emissions through incremental combustion
Use
• maximum application temperatures 2100 – 2375°F (1.150°C – 1.300°C) depending on the model
• use as radiant tube burner (metallic or fully ceramic radiant tube) for heat treatment plants with protective gas or other critical atmospheres
| Possible lengths in mm |
0 C |
395 |
475 |
556 |
|
636 |
|
1 C |
|
|
545 |
593 |
641 |
689 |
2 C |
|
|
545 |
613 |
|
681 |
3 C |
|
|
545 |
617 |
|
689 |
| Possible lengths in Inch |
0 C |
15 ½" |
18 ¾" |
22" |
|
25" |
|
1 C |
|
|
21 ½"
|
23 3/8"
|
25 ¼"
|
27 1/8"
|
2 C |
|
|
21 ½" |
24 1/8"
|
|
26 ¾"
|
3 C |
|
|
21 ½" |
24 1/8"
|
|
27 1/3"
|
|